"C","快活app官网. Morning Report" "C","Filename: morning_report_20250711_20250711114615000.csv" "C","Report for 07/11/2025" "C","Report generated 07/12/2025 07:40:50 EDT" "H","Report Type" "D","Operational Capacity Update Report" "H","Section 1. Report Date","Report Time" "D","07/11/2025","00:00:00" "H","Section 2. Prior Day Peak","Hour Ending","MW" "D","07/10/2025","20","16683" "H","Section 3. Operable Capacity Analysis" "H","Description","MW" "D","A. Capacity Supply Obligation (CSO)",26074 "D","B. Capacity Additions EcoMax Bid > CSO",730 "D","C. Generation Outages and Reductions (Planned + Forced)",2581 "D","Generation Planned Outages and Reductions",1445 "D","Generation Forced Outages and Reductions",1136 "D","D. Uncommitted Available Generation (Non-fast start)",2945 "D","Uncommitted Available Generation Non-fast Before Peak (Info Only)",643 "D","E. DRR Capacity",224 "D","F. Uncommitted Available DRR",12 "D","G. Capacity Deliveries: Net Purchases = (-) Net Sales = (+)" "D","Highgate",-225 "D","NB",-327 "D","NECEC",0 "D","NY快活app官网 AC",-250 "D","NY快活app官网 CSC",330 "D","NY快活app官网 NNC",-39 "D","Phase 2",-1155 "D","Net Deliveries",-1666 "D","H. Total Available Capacity (A+B-C-D+E-F-G)",23156 "D","I. Peak Load Forecast For Hour Ending19",18450 "D","J. Total Operating Reserve Requirement",2115 "D","K. Capacity Required = I + J",20565 "D","L. Surplus = (+) Deficiency = (-) (H - K)",2591 "D","M. Replacement Reserve Requirement",160 "D","N. Excess Commitment Surplus = (+) Deficiency = (-) (L - M)",2431 "D","Section 4. Largest First Contingency MW",1249 "D","Section 5. Annual Maintenance Schedule (A.M.S) Peak Load Exposure MW",24803 "H","Section 6. Reserve Summary" "D","Ten Minute Reserve Requirement:",1499 "D","Ten Minute Reserve Estimate:",1499 "D","Thirty Minute Reserve Requirement:",616 "D","Thirty Minute Reserve Estimate:",3207 "D","Expected Actions of OP 4:",0 "D","Additional Capacity Available from OP 4 Actions:",0 "H","Section 7. Interchange Summary" "H","Description","Import Limit MW","Export Limit MW","Scheduled Contract MW" "D","Highgate",-225,0,-225 "D","NB",-1000,200,-327 "D","NECEC",0,0,0 "D","NY快活app官网 AC",-1400,1200,-250 "D","NY快活app官网 CSC",-346,330,330 "D","NY快活app官网 NNC",-125,125,-39 "D","Phase 2",-2000,1200,-1155 "H","Section 8. Weather Forecast Summary for the Peak Hour" "H","City","Conditions","Wind","High Temperature (F)" "D","Boston","Mostly Cloudy","SE-12",74 "D","Hartford","Thunderstorms","S-9",81 "H","Section 9. Units Committed to Meet Minimum Operating Reserve and Replacement Reserve Requirements" "H","Number of Units","MW" "D",0,0 "H","Section 10. Report Comments" "D","" "T","46 lines"